Flow - Ultrasonic Flow Meters : ISM 5.0 Insertion Magmeter

Greyline Instruments

Greyline ISM 5.0 Insertion MagmeterGreyline ISM 5.0 Insertion Magmeter
ISM 5.0 Installation Through a Ball Valve
Installs through a Ball Valve into the pipe
Operates based on Faraday’s Law of electromagnetic induction

ISM 5.0 Insertion Magmeter


  • electromagnetic with no moving parts

  • simplified hot tap insertion design

  • installs in 3-72" (80-1800 mm) diameter pipes

  • selectable 4-20mA, 0-5V or 0-10V output

  • 0-500Hz frequency output

  • scalable pulse output


Description

ISM 5.0 Insertion Magmeter
The Accurate, Low Cost Alternative to Full-bore Magnetic Flow Meters

Measure flow of water and conductive liquids in full pipes from 3 to 72" (80 to 1800 mm) diameter.

The ISM 5.0 dual pair electrode sensor inserts through a tap in the pipe wall. It can be easily installed in new pipe systems or by hot tap in pressurized pipes with flowing liquids. There are no moving parts so obstruction to flow and pressure drop is minimal. Installation through a full port ball valve allows easy retraction and reinsertion without shutting down flow. The insertion depth is adjustable according to the pipe diameter and an insertion depth gauge is supplied with each flowmeter. The optional Installation Hardware Kit includes a branch outlet, close nipple and full port 1” isolation valve. 

The ISM 5.0 Insertion Magmeter senses flow using a low maintenance electromagnetic design with no moving parts. The dual-electrode sensor and continuous auto-zero function provides high accuracy – even at low flow rates. State-of-the-art electronics and patented design features help maintain its NIST traceable accuracy over time.

No Onsite Calibration Required

Based on your pipe type and size, liquid and flow rate each ISM 5.0 Insertion Magmeter is shipped from our factory configured for your application and ready to install. Connect the isolated 4-20mA output to control system or remote display, or use the relay pulse output.

ISM
Installs through a Ball Valve into the pipe

How It Works

The ISM 5.0 Insertion Magmeter operates based on Faraday’s Law of electromagnetic induction: as flow velocity of a liquid increases through the magnetic field generated by the sensor head of the ISM flow meter, electrodes measure the voltage increase to accurately calculate flow. Four electrodes measure the induced voltage on opposite sides of the sensor. The voltage readings are sampled and averaged.

The ISM 5.0 Insertion Magmeter measures flow of electrically conductive liquids (20 µS/cm or greater) in full pipes. For proper measurement on plastic pipes the electromagnetic flow meter requires electrical grounding by connection to grounding rings or ground probes inserted into the pipe. Readings are not affected by the fluid temperature, pressure or viscosity.

 

Operation based on Faraday’s Law of electromagnetic induction

Contact Greyline Instruments for specific recommendations in your application.

 

Related Products

Canada

Greyline Instruments Inc. Canada
16456 Sixsmith Drive, Long Sault, Ont. K0C 1P0
Tel: 613-938-8956 • Toll Free: 855-300-9151
Fax: 613-938-4857 • E-mail: info@greyline.com

United States

Greyline Instruments Inc. United States
11451 Belcher Road South, Largo, FL 33773
Tel: 315-788-9500 • Toll Free: 888-473-9546
Fax: 315-764-0419 • E-mail:  info@greyline.com