Greyline Portaflow SE Portable
Transit Time Flow Meter
Standard features include:
sensors - clamp-on, 1 MHz ultrasonic for
pipes from 2" to 40" ID (50 mm to 1000 mm)
sensor cable - 6 ft (3 m) with quick
couplings
sensor mounting kit - includes stainless
steel guide rail, mounting chains, and coupling compound
enclosure - portable, ABS electronics
enclosure with lockable carrying case
displays - backlit LCD matrix. Displays
flow in m3, liters or gallons (per minute or hour) and flow velocity in
ft/sec or m/sec. Displays positive and negative flow values and totals in
numeric or graph formats
totalizer - 12 digits, displays separate
forward and reverse flow totals
calibration - built-in 16-key calibration
system. Stores calibration parameters for up to 20 sites
power input - built-in rechargeable NiMH
battery with external charger rated 100-240VAC 50/60Hz
outputs - 4-20mA (750 ohm), RS232C with programmable baud rates
data logger - 50,000 data point capacity
1 manual
PORTABLE TRANSIT TIME FLOW METER SPECIFICATIONS
SCOPE: This specification covers a portable, ultrasonic
Transit Time flow meter by Greyline Instruments,
Massena, New York / Long Sault, Ontario. This instrument shall
provide for non-intrusive flow measurement, indication,
totalizing and transmitting of the flow rate in a full pipe.
GENERAL:
Each portable Transit Time flow meter shall have the following
design features and engineering specifications:
A. PERFORMANCE SPECIFICATIONS
Have an accuracy of ±2% of reading in most
clean fluid applications. Have repeatability
of ±0.5%.
Operate on clean liquids in full pipes
with less than 2% solids or gas bubbles.
Operate on the following pipe materials: carbon steel,
stainless steel, PVC, PVDF, fiberglass, galvanized steel, mild steel,
glass, copper, brass and pipes with bonded liners including epoxy, rubber
and Teflon.
Operate on AC/DC power. Include an internal
NiMH rechargeable battery with minimum capacity for 6-10 hours continuous battery operation. Recharge and operate
with power input of 100-260VAC 50-60Hz.
B. TRANSDUCERS
Have a dual transmitting/receiving,
clamp-on transducers.
The transducers shall be waterproof and operate
continuously at temperatures from -4°F to 257°F (-20°C to 125°C).
The transducer shall be designed to install on pipes with
inside diameter ranging from 2" to 40" (50 mm to 1000 mm).
Have a 6 ft (2 m) long
cable from the transducers to the electronics.
Shall include manufacturer's recommended sensor coupling
compound.
Shall include stainless steel mounting
rack with spring-loaded clamps.
C. ELECTRONICS
Have a portable, hand-held ABS enclosure
plus a padded carrying case containing the flowmeter, sensors and
accessories. Total shipping weight shall not exceed 18 lbs (8 kg).
Electronics shall be designed for continuous operation at
temperatures from 32° to 122°F (0° to 50° C).
Have a built-in 16-key programmer with
user-friendly calibration menu.
Have a backlit graphics display indicating
positive and negative flow rates and flow totals, flow graphs, calibration
menu, signal strength, battery charge status, date and time.
Have flow proportional 0/4-20mA output rated to maximum
resistive load of 750 ohms.
Have a built-in 50,000 point data logger, RS232C serial
output and connecting cables. Data logger shall support
time and date-stamped logging in user-selectable time periods.
Have
automatic signal strength monitoring and indication.
Have a battery status indicator with automatic low
battery shut off and battery overcharge protection.
D. MANUFACTURER
The instrument shall be a Portaflow SE Portable
Transit Time Flow
Meter by Greyline Instruments Inc., and warranted
against defects in materials and workmanship for one year.
Specifications are subject to change without
notice.
Please contact Greyline if you need more information
or for advice in your application. We can provide quotations and refer you to
the Greyline sales representative in your area. (To
receive complete information please provide your name,
mailing address, phone and fax numbers):